How AI and Smart Monitoring Help Utilities Detect Water Leaks
How utilities use flow, pressure and consumption data to identify hidden leaks and prioritise field inspections
AI helps water utilities detect potential leaks earlier by identifying unusual patterns in flow, pressure and consumption. Smart monitoring provides the measurements, while hydraulic analysis and field inspections help engineers determine whether a leak exists and where it is likely to be.
Underground leaks can develop for weeks before water appears at the surface. In the meantime, they can reduce network pressure, increase the volume of water a utility needs to produce and damage surrounding infrastructure. For utilities managing large distribution networks, monitoring helps narrow down where field teams should investigate first.
What data supports water leakage detection?
Flow and pressure naturally change as customer demand fluctuates, pumps start and stop, and valves are adjusted. Engineers need to understand these patterns before they can recognise signs of leakage. This is a core part of Water Network Design & Operations.
- SCADA systems provide operating data from pumps, reservoirs, valves and monitoring points.
- Smart meters help engineers establish typical consumption patterns and account for legitimate changes in demand.
- Pressure and flow sensors show how hydraulic conditions change at selected points across the network.
- Geographic information systems (GIS) connect readings to pipe locations, asset records and network boundaries.
- District metered areas (DMAs) allow utilities to measure flows into and, where applicable, out of defined zones.
Before using these measurements for analysis, check sensor accuracy, align timestamps and confirm that records reflect changes in pump schedules, valve positions and network configuration. A change in how the network is operated can otherwise look like a leak.
How AI identifies potential water leaks
Consider a district where water demand normally falls overnight. If minimum night flow rises over several nights without a corresponding change in legitimate consumption, the increase may point to leakage and warrant investigation.
A fixed-threshold alarm flags a reading once it passes a set limit. Machine-learning models can also compare flow, pressure, time of day and consumption together to identify changes that are harder to spot in a single reading. Anomaly detection flags departures from typical conditions, while forecasting compares observed readings with expected demand or pressure.
Engineers should check each alert against operating records before sending a field team. Changes in demand, pumping or valve settings can produce similar patterns. A model trained in one district may also need recalibration before it is used in another.
How engineers locate and confirm a leak
An alert can identify a district that needs investigation. Pressure readings and hydraulic modelling for water distribution systems can help narrow the search to specific pipe sections. Field teams can then use acoustic listening devices, leak noise correlators or targeted inspections to confirm the location.
Where a utility uses a digital twin, a calibrated hydraulic model linked to operational data can help engineers test which suspected locations best explain the observed pressure and flow changes. Its reliability depends on accurate pipe records, demand estimates and valve positions.
Recording confirmed leaks, false alarms and repair results helps utilities refine alert thresholds and identify where additional monitoring would improve detection.
Dubai example: Smart Ball leak detection in transmission pipelines
Dubai Electricity and Water Authority (DEWA) reported that its Smart Ball technology helped prevent the loss of 1.34 million cubic metres of water in 2024, with reported savings of AED 12 million. DEWA said it detected 180 leaks from the technology’s introduction in April 2021 through the end of 2024. dewa.gov.ae
The device travels through transmission pipelines and records sounds associated with leaks and other anomalies. Software then analyses the acoustic data to locate suspected faults. It illustrates how in-pipe inspection can help pinpoint leaks that broader network monitoring may only flag. dewa.gov.ae
How utilities measure leakage detection performance
Evaluate the monitoring system against operational outcomes:
- Time to detect. How long does it take to flag a suspected leak once abnormal behaviour becomes measurable?
- False alarm rate. What share of investigated alerts fail to identify a leak?
- Detection rate. What share of independently verified leaks did the system flag?
- Localisation accuracy. How close are predicted locations to confirmed leaks?
- Time to repair. How long does it take to resolve a confirmed leak?
- Verified water savings. How much have physical losses fallen against a baseline that accounts for changes in demand and operating conditions?
Build practical skills in water network monitoring
Energy Training Centre’s AI for Water Network Intelligence & Leakage Detection training course examines how utilities can use operational data and analytics to identify potential leaks and guide investigations.
Popular Training Venues
Popular Training Categories
Explore More Training Insights
Discover expert tips, industry trends, and best practices to enhance your professional development journey.
View All Articles